This is a Parts and Service Manual for the BreatheSafe DH INCO2 cabin pressurisation and air filtration system, specifically for Sumitomo SH210LC-6 and SH490LHD-6 Excavators. The manual details the system's components, installation procedures, and maintenance schedules, including instructions for filter replacement and troubleshooting. It ensures compliance with air quality standards by providing HEPA-filtered and positively pressurised cabin air.
Specifications
| system type | Dual HEPA (DH) Integrated CO2 (INCO2) cabin pressurisation and air filtration system |
| wiring configuration | 20A wiring |
| pressuriser type | HEPA H14 Variable Speed Pressuriser |
| cabin display | INPRESS TS Cabin Display with CO2 Sensor |
| return air filter | HEPA Return Air Filter |
| blower | Brushless Blower P/N 200002 |
| voltage | 24VDC |
| current draw | 11 amps (peak) |
| air flow | Up to 30-300 m3/h or 50-215 CFM |
| pre cleaner | Integrated VLR (Very Low Restriction) Turbo Pre-Cleaner |
| filter element | BreatheSafe HEPA Primary Filter (H14=99.99% MPPS) tested as per EN1822 – P/N 500000 |
| plugs fittings | Mining spec Deutsch electrical plugs as standard |
| construction | High strength composite construction |
| maintenance interval | Inspect every 500 hours, replace HEPA filter when 80% or greater capacity |