Manitou
Other
No image
Manitou - Telehandler - MHT-860 - DH INCO2
700039
Description
This is a Breathe-safe Parts and Service Manual for the DH INCO2 cabin pressurisation and air filtration system, specifically designed for the Manitou MHT-860 Telehandler. It provides comprehensive technical information for installation, operation, and maintenance of the system. The manual covers safety procedures, component details, and troubleshooting guidelines to ensure optimal performance and compliance with air quality standards.
Specifications
| System Type | DH INCO2 (Dual HEPA, INPRESS TS Cabin Display with CO2 Sensor) |
| Voltage | 12V DC or 24V DC |
| Current Draw | 11 amps (peak) for 24VDC systems |
| Air Flow | Up to 30-300 m3/h or 50-215 CFM |
| Filter Element | BreatheSafe HEPA Primary Filter (H14=99.99% MPPS) TESTED AS PER EN1822 – P/N 500000 |
| Pre-cleaner | Integrated VLR (Very Low Restriction) Turbo Pre-Cleaner |
| Plugs & Fittings | Mining Spec. Deutsch electrical plugs as standard |
| Construction | High strength composite construction |
| Maintenance Schedule | 500-hour inspections, filter replacement when capacity is over 80% |
Vehicle / Equipment Applications
Manitou MHT-860 Telehandler
Documents
Weight: 1 kg